admin (1) aix (1) alert (1) always-on (2) Architecture (1) aws (3) Azure (1) backup (3) BI-DWH (10) Binary (3) Boolean (1) C# (1) cache (1) casting (3) cdc (1) certificate (1) checks (1) cloud (3) cluster (1) cmd (7) collation (1) columns (1) compilation (1) configurations (7) Connection-String (2) connections (6) constraint (6) copypaste (2) cpu (2) csv (3) CTE (1) data-types (1) datetime (23) db (547) DB2 (1) deadlock (2) Denali (7) device (6) dotNet (5) dynamicSQL (11) email (5) encoding (1) encryption (4) errors (124) excel (1) ExecutionPlan (10) extended events (1) files (7) FIPS (1) foreign key (1) fragmentation (1) functions (1) GCP (2) gMSA (2) google (2) HADR (1) hashing (3) in-memory (1) index (3) indexedViews (2) insert (3) install (10) IO (1) isql (6) javascript (1) jobs (11) join (2) LDAP (2) LinkedServers (8) Linux (15) log (6) login (1) maintenance (3) mariadb (1) memory (4) merge (3) monitoring (4) MSA (2) mssql (444) mssql2005 (5) mssql2008R2 (20) mssql2012 (2) mysql (36) MySQL Shell (5) network (1) NoSQL (1) null (2) numeric (9) object-oriented (1) offline (1) openssl (1) Operating System (4) oracle (7) ORDBMS (1) ordering (2) Outer Apply (1) Outlook (1) page (1) parameters (2) partition (1) password (1) Performance (103) permissions (10) pivot (3) PLE (1) port (4) PostgreSQL (14) profiler (1) RDS (3) read (1) Replication (12) restore (4) root (1) RPO (1) RTO (1) SAP ASE (48) SAP RS (20) SCC (4) scema (1) script (8) security (10) segment (1) server (1) service broker (2) services (4) settings (75) SQL (74) SSAS (1) SSIS (19) SSL (8) SSMS (4) SSRS (6) storage (1) String (35) sybase (57) telnet (2) tempdb (1) Theory (2) tips (120) tools (3) training (1) transaction (6) trigger (2) Tuple (2) TVP (1) unix (8) users (3) vb.net (4) versioning (1) windows (14) xml (10) XSD (1) zip (1)
Showing posts with label cpu. Show all posts
Showing posts with label cpu. Show all posts

A script that make high CPU utilization

USE master


SELECT MyInt = CONVERT(BIGINT, o1.object_id) + CONVERT(BIGINT, o2.object_id) + CONVERT(BIGINT, o3.object_id)

INTO #temp

FROM sys.objects o1

JOIN sys.objects o2 ON o1.object_id < o2.object_id

JOIN sys.objects o3 ON o1.object_id < o3.object_id


SELECT SUM(CONVERT(BIGINT, o1.MyInt) + CONVERT(BIGINT, o2.MyInt))

FROM #temp o1

JOIN #temp o2 ON o1.MyInt < o2.MyInt

AIX - CPU, memory and IO (disks space) commands

CPU usage for each process:
topas –P

CPU details:
mpstat

Memory details:
vmstat
svmon

Disk IO details:
iostat
topas -D